PAGE #19
"10" SERIES
If the Ashcraft C-70 arc lamp is utilized, specify the reflector as 14" diameter with 34" working
distance, 5-5/32" focus, Stromg Specification 34 or equal.
Arc lamp equipment may range from 15 ampere to 70 ampere capacity.
OPTIONAL EQUIPMENT AND ACCESSORIES:
1 - #1640 - Pair 35mm 2000 foot capacity clamp-type rewinder.
1 - #1809 - R-2 35mm film splicer.
RECOMMENDED SPARE PARTS AND OPERATING SUPPLIES:
6 - # 399 - Exciter Lamp
1 - # 400 - Amplifier Pilot Lamp
6 - # 411 - Framing and Threading Lamp
1 - #1618 - 1 Pint Can Film Cement
1 - #1840 - 1 Pint Can Chain Oil
1 - #1866 - 1 Pint Can General Mechanism Oil
1 - #1874 - 1 Pint Can Intermittent Oil
2 - #3800 - 115 Volt Changeover Coil
4 - #4085 - Amplifier Fuse
2 - #4259 - Changeover Microswitch
2 - #4301 - 6 J 7 Amplifier Tube
2 - #4310 - 5 U 4 G Amplifier Tube
2 - #4314 - 6 N 7 G Amplifier Tube
4 - #4327 - 6 L 6 G Amplifier Tube
2 - #4362 - 6 S F 5 Amplifier Tube
2 - #4453A2 - Photo Electric Cell
6 - #5819 - 2000 foot, 35mm Welded wire Reel
CONVERSIONS:
Factory or Field - Convertible for projection of Cinemascope or Superscope Film
(See Conversions Pages 25 and 27.)
Factory or Field - Convertible for projection of Non-anamorphic Vistavision Film
(See Conversions Page 25.)
Factory or Field Conversion of One Model "XDC" Projector to Current Model "10" Specify:
1 - # 8897 - Aperture Roller Kit
1 - #10981 - Chain Idler Slide Kit Assembly
1 - #12272 - Fixed Idler Assembly
1 - #12415 - Intermittent-Feed Driving Chain
1 - #12416 - Shutter Driving Chain
1 - #12570 - Barrel Film Shutter and Fire Shutter Kit Assembly
1 - * - "XDC" to "10" Instruction Sheet.
"XDC" to "10" conversion expecially recommended in conjunction with Cinemascope conversion.